3 detection settings (func), Output timer, Detection settings (func) -7 – KEYENCE FS-N10 Series User Manual

Page 53: Output timer -7, Detection settings (func)

Advertising
background image

4

Set

tings
f

o

r

Ad
v

an
ced F

u

nct
ion
s

4-7

- Digital Fiber Sensor FS-N10 Series User's Manual -

4-3

Detection Settings (Func)

There are 3 types of timers available.

* Example of the light-ON (L-on) mode for the reflective model and the dark-ON (d-

on) mode for the thrubeam/retro-reflective

• When using the 2-output type, different timer functions and timer times

can be set separately for channels 1 and 2.

"Output Timer for Output2" (page 4-38)

• The timer can only control on/off switching of the sensor output.

Output Timer

Refer to page 4-2 "Detection Settings (Func)" for setting methods.

Display

Function

Timing chart

*

toFF

Uses no output timer. (Default)

oFFd

Off-delay timer
Turns off the output at a specified
time after the detection signal
goes off.
Setting range: 1 to 9999 ms
Default: 10 ms

on-d

On-delay timer
Turns on the output at a specified
time after the detection signal
goes on. Useful if the ON duration
is limited because the workpiece
is shaky such as by vibration.
Setting range: 1 to 9999 ms
Default: 10 ms

Shot

One-shot timer
Turns on the output and keeps it
on for a specified period after the
detection signal goes on.
Setting range: 1 to 9999 ms
Default: 10 ms

OFF

ON

With workpiece Without workpiece

Without workpiece

Control output

Timer-set period

OFF

ON

With workpiece Without workpiece

Without workpiece

Control output

Timer-set period

OFF

ON

With workpiece Without workpiece

Without workpiece

Control output

Timer-set period

OFF

ON

With workpiece Without workpiece

Without workpiece

Control output

Reference