- Digital Fiber Sensor FS-N10 Series User's Manual -

4-2

Basic Settings

The detection stability will increase when the response time is delayed.
You can select from the following 6 power modes.
The response time slows down in the order of

hSP

,

FinE

,

turb

,

Supr

,

ULtr

,

MEGA

.

Detection distance varies depending on the fiber units to be combined. For specific
numerical values, refer to the catalogues and specifications of the fiber units
concerned.

When using the unit in point-blank range, raising the power mode exces-

sively may attenuate the received light intensity. In such a case, either
lower the power mode or use the saturation Canceling function.

"Light emission/Received light intensity adjustment (Saturation

Canceling)" (page 3-18)

You can select from the following 3 sensitivity setting methods.

*

Refer to the following 2 pages for details.

Power Modes

Refer to page 4-2 "Basic Settings" for setting methods.

Display

Power mode name

Response time

hSP

HIGH SPEED mode

50 µs

FinE

FINE mode (Default)

250 µs

turb

TURBO mode

500 µs

SuPr

SUPER mode

1 ms

ULtr

ULTRA mode

4 ms

MEGA

MEGA mode

16 ms

Point

Sensitivity Setting

Refer to page 4-2 "Basic Settings" for setting methods.

Display

Sensitivity setting method

Reference

page

Std

Normal sensitivity setting (without correction) (Default)

3-5 to 3-14

SEtP

Percentage calibration

4-5

0SEt

Zero shift calibration

4-6