Light emission/Received light intensity adjustment (Saturation Canceling)

When a fiber unit having strong power (longer detection range) is used at a close
range, the received light intensity may remain unchanged from the maximum value in
the display-enabled range (saturated) regardless of whether a workpiece is present or
not. (Example: Numerical value does not change from 9999)
In such a case, the light emission and the received light intensity can be automatically
corrected to optimal state by using the saturation Canceling function.

Enabling the saturation Canceling function

1

Press the [SET] button while holding down the [MODE] button.

The received light intensity corresponding to the power mode is set within the
range as shown in the following table.

Disabling the saturation Canceling function

1

Press the [SET] button while holding down the [MODE] button.

Saturation Canceling function

Power mode

Setting range of

received light intensity

HSP

FINETURBO

2047±350

SUPER

4095±500

ULTRAMEGA

5000±600