Fs-n13cp/n14cp, Monitor output type, Fs-n11mn – KEYENCE FS-N10 Series User Manual
Page 93: Monitor output type -7
Advertising

5-2 Input/Output Circuit Diagram
5
Sp
eci
fic
at
io
ns
5-7
- Digital Fiber Sensor FS-N10 Series User's Manual -
FS-N13CP/N14CP
0 V
12 to 24 VDC
* FS-N13CP only
Sensor main circuit
(Control output 2)
(Control output 1)
Overcurrent protection circuit
Overcurrent protection circuit
Load
Load
1
2
3
4
M8 connector Pin layout
Monitor output type
FS-N11MN
0 V
12 to 24 VDC
Brown
Black
Monitor output
(1 to 5V)
*1
Orange
Blue
*1 Device with input impedance 10 k
Ω
or more
Sensor main circuit
Load
(Control output)
Overcurrent protection circuit
Protection circuit
Advertising