Monitor output type, Monitor output type -4, 1 specifications – KEYENCE FS-N10 Series User Manual

Page 90: Sp eci fic at io ns, Digital fiber sensor fs-n10 series user's manual

Advertising
background image

5-1 Specifications

5

Sp
eci
fic

at

io

ns

5-4

- Digital Fiber Sensor FS-N10 Series User's Manual -

*1

SUPER: 1.2ms, ULTRA:1.8ms, MEGA: 4.2ms 63% response

*2

Increased by 100 mW (4.0 mA) for HIGH SPEED mode.

*3

One or two units connected: -20 to +55 °C; 3 to 10 units connected: -20 to +50 °C,
11 to 16 units connected: -20 to +45 °C. When using 2-output type, one unit is counted as two units.
All temperature specifications are for when the unit is mounted on a DIN rail; and installed on metal frame.

Monitor Output Type

Type

Monitor output type

Input/Output configuration

Cable

Main unit/Expansion unit

Main unit

Models

NPN

FS-N11MN

PNP

-

Number of
input/out-
put

Control output

1-output

Monitor output
(1-5V)

1-output

External input

-

Light source LED

Red 4-element LED (Wavelength: 630 nm)

Response time

50us(HIGH SPEED)/250us(FINE)/500us(TURBO)/1ms(SUPER)/4ms(ULTRA)/

16ms(MEGA)

Output toggle

Light-ON/Dark-ON toggle

Timer functions

Timer OFF/OFF delay/ON delay/One-shot

Output
specifica-
tions

Control output
(NPN)

NPN open collector 24 V or less, maximum 100 mA or less (stand-alone)/20 mA or less

(multiple connections)

Residual voltage: 1V or less

Monitor output

1 to 5 V voltage output; load resistance 10k

Ω

or more; repeatability +/-0.5% of F.S

1 ms response time, 63% response (HIGH SPEED, FINE, TURBO)

*1

Expansion units

Up to 16 units can be connected (total connection of 17 units including the main unit);

2-output type is treated as 2 units, however.

Protection circuit

Protection against reverse power connection, output overcurrent and output surge

Number of interference preven-
tion units

Up to 16 units can be connected, but may differ depending on the power mode.

0 for HIGH SPEED; 4 for FINE and 8 for TURBO/SUPER/ULTRA/MEGA

(These numbers double when "Double" is selected.)

Rating

Supply voltage

12-24 VDC +/- 10%, ripple (P-P) 10% or less

Power consumption

Normal: 900 mW or less (36 mA or less at 24 VDC; 48 mA or less at 12 VDC)

*2

ECO ON (All): 800 mW or less (32 mA or less at 24 VDC; 39 mA or less at 12 VDC)

*2

ECO Full: 470 mW or less (19 mA or less at 24 VDC; 23 mA or less at 12 VDC)

Environ-
ment resis-
tance

Operating ambient
luminance

Incandescent lamp: 20,000 lx or less; solar light: 30,000 lx or less

Operating ambient
temperature

-20 °C to +55 °C (no freezing)

*3

Operating ambient
humidity

35 to 85% RH (no condensation)

Vibration resistance

10 to 55 Hz Compound amplitude 1.5 mm, two hours for each of X, Y and Z axes

Shock resistance

500m/s

2

, 3 times for each of X, Y and Z axes

Case material

Both main unit and cover material: Polycarbonate

Case dimensions

H30.3mm x W9.8mm x L71.8mm

Mass

Approx. 75 g

Advertising