Two-point calibration is the most basic method of sensitivity setting.
The setting value can be established by simply pressing the [SET] button once each
when a workpiece is present. and when it is absent.

1

Press the [SET] button once
when no workpiece is pres-
ent.

2

Press the [SET] button once
when a workpiece is present.
Calibration is complete after
the setting value flashes
momentarily, and then stops
(lights up).

Press the

button to adjust

the setting value.

Step 1 or step 2 may be performed first.
When performing two-point calibration on channel 2 of the 2-output type,

set the channel switch to "

".

Two-point Calibration

Workpiece

Reference

If the difference between the 2 conditions is too small, "- - - -" flashes
after calibration is complete.
However, the setting value will still established.

Setting
value

Time

The setting value is set to the middle
of the values at which the [SET] button
was pressed first and pressed second.