Rockwell automation plc, Description of the reference program, Description of the reference program ... a-7 – KEYENCE IV Series User Manual

Page 101

Advertising
background image

A-7

- IV Series User’s Manual (Field Network) -

Reference program (EtherNet/IP)

Rockwell Automation PLC

Rung0

Rung1

REQ

ONS

ONS

Program Change

MOV

Move

Source

Dest

Number

Program Number

REQ

Program Change

Program Change Ack

„

„

Description of the reference program

„

z

Rung0

This line sets “REQ” to ON and copies the Number data, which contains the program No. to be set, to the
program No.

„

z

Rung1

Sets “REQ” to ON and executes “Program Change”.
“Program Change Ack” ON will set “Program Change” to OFF (“Program Change” will be retained until
“Program Change Ack” becomes ON).

A