Rung0
Rung1
REQ
ONS
ONS
Program Change
MOV
Move
Source
Dest
Number
Program Number
REQ
Program Change
Program Change Ack
Description of the reference program
z
Rung0
This line sets “REQ” to ON and copies the Number data, which contains the program No. to be set, to the
program No.
z
Rung1
Sets “REQ” to ON and executes “Program Change”.
“Program Change Ack” ON will set “Program Change” to OFF (“Program Change” will be retained until
“Program Change Ack” becomes ON).