- IV Series User’s Manual (Field Network) -

Data allocations in the data I/O communication

Tool Result Modules (IV series→ PLC)

Tool Result Modules are modules that write responses from the IV series to the PLC.
The device map of the data allocated for the Tool Result Modules is as shown below.
Stores the matching rate and threshold information of the position correction and other tools.
For details of each parameter, refer to “Tool Result Modules parameter details” (Page 5-28).

z

„

Position Adjust Result

Slot No.: 6
Module size: 20 bytes

Address

Bit7

Bit6

Bit5

Bit4

Bit3

Bit2

Bit1

Bit0

0 - 1

Position correction score (Unsigned 16-bit data)

2 - 3

Position correction score MAX (Unsigned 16-bit data)

4 - 5

Position correction score MIN (Unsigned 16-bit data)

6 - 7

Position correction score Lower threshold (Unsigned 16-bit data)

8 - 19

Reserved by system

z

„

Tool Result

Slot No.: 7 to 22
Module size: 20 bytes

Address

Bit7

Bit6

Bit5

Bit4

Bit3

Bit2

Bit1

Bit0

0 - 1

Tool score (Unsigned 16-bit data)

2 - 3

Tool score MAX (Unsigned 16-bit data)

4 - 5

Tool score MIN (Unsigned 16-bit data)

6 - 7

Tool lower threshold (Unsigned 16-bit data)

8 - 9

Tool upper threshold (Unsigned 16-bit data)

10 - 19

Reserved by system