Device statistics address 0 to 27, Statistics information) -27 – KEYENCE IV Series User Manual

Page 85

Advertising
background image

5-27

- IV Series User’s Manual (Field Network) -

Data allocations in the data I/O communication

z

„

Device Statistics Address 0 to 27 (Statistics information)

The Bits at Address 0 to 27 of the Device Statistics have the following functions:

Address

Data

type*

Item

Content

Data content

0 to 1

WORD

Processing time MAX

Displays the maximum

processing time value.

0 to 10000

2 to 3

WORD

Processing time MIN

Displays the minimum

processing time value.

0 to 10000

4 to 5

WORD

Processing time AVE

Displays the average processing

time value.

0 to 10000

6 to 7

---

Reserved by system

---

---

8 to 11

DWORD Number of triggers

Displays the total number of

triggers issued.

0-999999999

12 to 15

DWORD Number of OKs

Displays the total number of

triggers issued whose overall

status result was “OK”.

0-999999999

16 to 19

DWORD Number of NGs

Displays the total number of

triggers issued whose overall

status result was “NG”.

0-999999999

20 to 23

DWORD Number of trigger errors Number of triggers issued that

generated a trigger error

0-999999999

24 to 27

---

Reserved by system

---

---

* WORD :

Unsigned 16-bit integer

DWORD : Unsigned 32-bit integer

y

The unit of processing time is msec.

y

The maximum number of triggers is 999999999. If the maximum value is exceeded, it will go back to 0
and start counting up again.

y

The maximum value for the number of OK triggers, number of NG triggers, and the number of trigger
errors is 999999999. The value will stop updating when the upper limit value is reached.

y

A reset will occur in the following conditions:

y

When [Statistics reset] is input

y

When a tool is added/deleted/copied

y

When the enable/disable status of the upper threshold value for the color area/area tool or the
setting scale has been changed via user operation or tool auto-tuning

y

When a tool auto-tuning is started with two or more tools other than the position correction tool set

y

When the sensor is switched OFF

y

When the program is switched

y

When a correction for the sensor is started

y

When the sensor is initialized

5

Data I/O communication

Advertising