- IV Series User’s Manual (Field Network) -
Data I/O communication setting method
Setting the Siemens TIA Portal
This following explains the setting method when
using TIA Portal.
1
Launch [TIA Portal V11] with the PC and
CPU connected.
2
Select the [Device & Networks] tab, and
then click [Add new device].
The [Add new device] screen will appear.
3
Select the CPU to be connected.
4
Right-click the selected CPU in [Project
tree], and then click [Open].
The [(Set device name [Selected CPU])] screen
will appear.
5
Set the IP address and subnet mask of
the CPU from [General] - [PROFINET
interface] - [Ethernet addresses], and then
click the [Add new subnet] button.
5
Data I/O communication