Control modules parameter details, Command control address 0 to 1: control request, Control modules parameter details -20 – KEYENCE IV Series User Manual

Page 78: Command control address 0 to 1, Control request -20

Advertising
background image

5-20

- IV Series User’s Manual (Field Network) -

Data allocations in the data I/O communication

Control Modules parameter details

z

„

Command Control Address 0 to 1: Control request

The Bits at Address 0 to 1 of the Command Control have the following functions:

Address

Bit

Item

Content

Data content

0

0

Trigger request

Requests the external trigger.

0 : OFF

1 : ON

1

Master image registration

request

Requests a master image

registration.

0 : OFF

1 : ON

2

Program switching

request

Requests a program switching. 0 : OFF

1 : ON

3

Warning clear request

Requests a warning clear.

0 : OFF

1 : ON

4

Statistics reset request

Requests a statistics reset.

0 : OFF

1 : ON

5

Buffer clear request

Requests a buffer clear.

0 : OFF

1 : ON

6 to 7 Reserved by system

---

---

1

0 to 7 Reserved by system

---

---

The following will occur when a buffer clear is requested:

y

If handshake control is [Enabled]

y

The current status result will be cleared.

y

The status result in the buffer will be cleared.

y

The result available bit will become OFF (0).

y

The number of remaining buffers will become “10”.

y

If handshake control is [Disabled]

y

The current status result will be cleared.

y

The result available bit will become OFF (0).

y

If you are switching programs using the PROFINET communication, set the [Switching method]

option to [Monitor/PC]. For details of the setting, Refer to the “IV Series User’s Manual (Monitor / PC

Software)”.

y

Buffer overrun and warning statuses will not be cleared even if you execute a buffer clear request.

5

Data I/O communication