KEYENCE IV Series User Manual

Page 67

Advertising
background image

5-9

- IV Series User’s Manual (Field Network) -

Data I/O communication setting method

11

Click the [Properties] tab. Select

[PROFINET interface [x1]] - [Ethernet

addresses] under [General], and then

select the IP address setting method for

the IV series.

z

z

To set a new IP address for the IV series

using the DCP protocol

z

z

To use the IP address that is already

registered for the IV series

y

If the IP address will be set by the DCP

protocol, the IP address of the sensor will be

initialized.

y

The IP address set by the DCP protocol will

be stored in the volatile memory.

When you restart the sensor, the sensor

will start up with its IP address in “----”

(unregistered) status.

12

Click the [Properties] tab. Select

[PROFINET interface [x1]] - [Advanced

options] - [Real time settings] in

[General], and then set the SendCycle

(communication cycle) for the data I/O

communication in [Update time].

13

Click the CPU in the [Devices] tab. Select

[Compile] - [All] and save the settings.

5

Data I/O communication