Output assembly (plc → iv series), Output assembly (plc → iv series) -19 – KEYENCE IV Series User Manual

Page 41

Advertising
background image

3-19

- IV Series User’s Manual (Field Network) -

Data allocation in the cyclic communication

Output Assembly (PLC IV series)

Output Assembly are devices that write instructions from the PLC to the IV series.
The device map of the data allocated for the Output Assembly is as shown below.
These parameters are responsible for the control instructions for the IV series, clearing of warnings and
handshake control.
For details of each parameter, refer to “Output Assembly parameter details” (Page 3-20).

Address

Bit7

Bit6

Bit5

Bit4

Bit3

Bit2

Bit1

Bit0

0

Reserved by system

Buffer

clear

request

Statistics

reset

request

Warning

clear

request

Program

switching

request

Master

registration

request

Trigger

request

1

Reserved by system

2

Reserved by system

Result

acquisition

complete

notification

3

Reserved by system

4 - 5

Program No.

6 - 11

Reserved by system

3

Cyclic communication

Advertising