Input assembly parameter details, Input assembly address 1: control error result, Input assembly parameter details -12 – KEYENCE IV Series User Manual

Page 34: Input assembly address 0, Control result (response) -12, Input assembly address 1, Control error result -12

Advertising
background image

3-12

- IV Series User’s Manual (Field Network) -

Data allocation in the cyclic communication

Input Assembly parameter details

z

„

Input Assembly Address 0: Control result (response)

The Bits at Address 0 of the Input Assembly have the following functions:

Address

Bit

Item

Content

Data content

0

0

Trigger response

Stores the external trigger

response.

0 : OFF

1 : ON

1

Master image registration

response

Stores the master image

registration response.

0 : OFF

1 : ON

2

Program switching

response

Stores the program switching

response.

0 : OFF

1 : ON

3

Warning clear response

Stores the warning clear

response.

0 : OFF

1 : ON

4

Statistics reset response Stores the statistics reset

response.

0 : OFF

1 : ON

5

Buffer clear response

Stores the buffer clear response. 0 : OFF

1 : ON

6 to 7 Reserved by system

---

---

z

„

Input Assembly Address 1: Control error result

The Bits at Address 1 of the Input Assembly have the following functions:

Address

Bit

Item

Content

Data content

1

0

Trigger failed

This bit is output when the

external trigger is unsuccessful.

0 : -

1 : The external trigger

has failed.

1

Master image registration

failed

This bit is output when the

master image registration is

unsuccessful.

0 : -

1 : Master image

registration has failed.

2

Program switching failed

This bit is output when

the program switching is

unsuccessful.

0 : -

1 : Program switching

has failed.

3 to 7 Reserved by system

---

---

3

Cyclic communication

Advertising