Warning code list, Warning code list -30 – KEYENCE IV Series User Manual

Page 88

Advertising
background image

5-30

- IV Series User’s Manual (Field Network) -

Data allocations in the data I/O communication

Warning code list

The following shows the list of warning codes that are generated in the IV series.

Warning

code

Content

Cause

Countermeasure

0

No error

---

---

62

Field network overrun

error

An overrun of the status

result has occurred.

Request a result acquisition completion

notice to permit the updating of the

status result.

63

Field network bad

request error (Master

registration)

External master registration

has been requested from

PROFINET while the unit

is in “Setting” status.

Do not request an external master

registration while the unit is in “Setting”

status.

64

Field network bad

request error

(Program switching)

y

Program switching has

been requested from

PROFINET while the

unit is in “Setting” status.

y

A program switching

request to a non-existent

program No. was made

from PROFINET.

y

A program switching

requested was made

from PROFINET while

the program switching

method was set to

[External input].

y

Do not request a program switching

while the unit is in “Setting” status.

y

The program No. should be set in the

range between 0 and 31.

y

If you are switching programs from

PROFINET, set the program switching

via external input to [Disabled].

65

Trigger error

A trigger has been input

while the unit was in busy

status. (If you have set

the trigger error option to

[Enabled])

Do not input triggers while the unit is in

busy status.

66

External master

registration error

(Insufficient outline)

The outline tool is unable

to extract the outline of the

new master image.

y

Check if there are any problems with

the registered image and the detection

tool or the position correction setting.

y

Adjust the brightness of the image to

be registered.

67

External master

registration error

(Insufficient area)

The color area/area tool is

unable to extract the area

of the new master image.

68

External master

registration error

(Brightness correction

failed)

The brightness of the new

master image cannot be

corrected appropriately.

5

Data I/O communication

Advertising