AERCO RECON 1000 User Manual

Page 89

Advertising
background image

RECON Water Heaters Installation, Operation & Maintenance Manual

CHAPTER 6 – MAINTENANCE

OMM-0103_0A

AERCO International, Inc.

 100 Oritani Dr.  Blauvelt, NY 10913

Page 89 of 178

GF-147

Phone: 800-526-0288 PRI:

10/28/2014

Figure 6-8: Anode Assembly and Combustion Chamber Head

6.8 HEAT EXCHANGER CLEANING

AERCO recommends that the heat exchanger of the unit be cleaned annually to maintain
maximum heat transfer efficiencies using a solution of HydroSkrub and water. HydroSkrub is
distributed by AERCO International, Inc. and is designed to dissolve the toughest water scale,
lime, mud and rust deposits from virtually any type of water-based equipment.

--WARNING! -

Please review MSDS, specifications, and our website
(www.aerco.com

)

for additional information, or call technical service

at (800) 526-0288.

Do not drain the unit without venting the shell! A vacuum in the unit
may displace the head liner causing serious damage not covered
by warranty.