3

ELECTRIC CONNECTION

3.1

Electric connection

The following drawing illustrates the devices' electric connection.

The utility managed by the K4 digital output, depends on the configuration parameter u1, as follows:

-

extraction hood (parameter u1 = 0, factory setting)

-

multifunction (u1 = 1).

The utility managed by the K5 digital output, depends on the configuration parameter u11, as follows:

-

technical compartment fan (parameter u11 = 0, factory setting)

-

switch-on/off (u11 = 1).

For the settings relative to the configuration parameters, see chapter 14 “CONFIGURATION”.

The TTL port is the communication port with the EVKEY programming key.

The RS-485 port is the communication port with the following EVCO products:

-

parameters Manager set-up software system

-

device for recording data and to download recorded data (via USB) EVUSBREC01.

-

RICS plants monitoring and surveillance systems

The port must not be used simultaneously with more than one of these products.