Operate as follows to exit the procedure before the operation

is complete:

10.

Do not operate for 15 sec (any changes will be

saved).

It is also possible to set the tOn time through the tOn

parameter, the tOF time through the tOF parameter and the

nCY number through the nCY parameter.

It is also possible to set the time tOn via the tOn parameter.

7.1.4

Manual activation of steam injection (only if

parameter t0 is set at 0)

Operate as follows to activate steam injection in manual

mode:

1.

Make sure that the device is on, that there is no

other procedure in progress and that steam

injection is allowed (see parameter P4).

2.

Press and release the "STEAM INJECTION" key:

the steam injector will be switched on for the time

established with the tOn parameter or for the

entire duration the key is pressed.

7.1.5

Activation of steam injection in cyclical

mode(only if parameter t0 is set at 1)

Operate as follows to activate steam injection in cyclical mode:

1.

Make sure that the device is on, that there is no

other procedure in progress and that steam

injection is allowed (see parameter P4).

2.

Press and release the "STEAM INJECTION" key:

the steam injector will be switched on in cyclic

mode (at maximum for the number of cycles

established with the nCY parameter or until the

key is pressed and released again. The time

defined with the tOn parameter establishes the

switch-on duration of the injector and that defined

with the tOF parameter that of switch-off) or for

the entire duration that the key is pressed.

7.2

Steam generator

7.2.1

Preliminary notes

Steam generator activity depends mainly on parameter P4, as

follows:

-

if parameter P4 is set at 0 or 1, pressing and

releasing the “STEAM GENERATOR” key cause the

steam generator to switch on (until the key is

pressed and released again)

-

if parameter P4 is set at 2, pressing and releasing

the “STEAM GENERATOR” key will activate steam

temperature adjustment (until the key is pressed

and released again; the temperature defined with

the SPS parameter establishes the steam set-

point, that defined with the t3 parameter, the

differential and that established with the t4

parameter, that below which steam injection is

disabled).

7.2.2

Switching on the steam generator (only if

parameter P4 is set at 0 or 1)

Operate as follows to switch the steam generator on:

1.

Ensure that the device is switched on and that no

other procedure is in progress.

2.

Press and release the "STEAM GENERATOR" key:

the steam generator will be on (until the key is

pressed and released again).

7.2.3

Activation of steam injection temperature

adjustment (only if parameter P4 is set at 2)

Operate as follows to activate the steam temperature

adjustment:

1.

Ensure that the device is switched on and that no

other procedure is in progress.

2.

Press and release the "STEAM GENERATOR" key:

the steam temperature adjustment will be

activated (until the key is pressed and released

again).