EVCO EVF328J9 User Manual

Page 46

Advertising
background image

EVCO S.p.A.

EVF 300 series | Installer manual ver. 1.1 | Code 144F300E114

Page 46 of 62

15

SIGNALS

15.1

Signals

The following table illustrates the meaning of the device LEDS.

LED

MEANING

"UPPER" display

if the parameter CFG is set at 0, chamber LED

if it is on, the top output and/or the floor output will be on

if it flashes, setting of the work set-point will be in progress (with the procedure illustrated in paragraph

14.2)

if the parameter CFG is set at 1, top LED

if it is on, the top output will be on

if it flashes, setting of the top set-point will be in progress (with the procedure illustrated in paragraph 14.3)

in the "LOWER"

display

floor LED

if it is on, the floor output will be on

if it flashes, setting of the floor set-point will be in progress (with the procedure illustrated in paragraph

14.3)

M:F

Multifunction LED

if it is on, the multifunction output will be on

Energy Saving LED

if on, the "energy saving" function is in progress

CYCLES

number of steam injections in cyclic mode LED

if it is on, the value shown in the floor part of the “LOWER” display will be the residual count of the number

of steam injections in cyclical mode and the activation mode of the steam injector will be “AUTOMATIC +

PERSISTENT MANUAL”

T

ON

switch-on duration of the steam injector LED

if it is on, the value shown in the floor part of the "LOWER" display will be the minimum duration of steam

injector switch-on and the activation mode of the steam injector will be "MANUAL + PERSISTENT MANUAL"

if it flashes, quick setting of the time tOn will be in progress (i.e. of the switch-on duration of the steam

injector, with the procedures illustrated in the chapter 7.1)

T

OFF

switch-off duration of the steam injector LED

if it flashes, quick setting of the time tOF will be in progress (i.e. of the switch-off duration of the steam

injector, with the procedures illustrated in the chapter 7.1)

In the "UPPER"

display

if the parameter CFG is set at 0, temperature associated to the chamber LED

if it is on, the value displayed in the top part of the display will be a temperature associated to the chamber

if it flashes, setting of the work set-point will be in progress (with the procedure illustrated in paragraph

14.2)

if the parameter CFG is set at 1, temperature associated to the top LED

if it is on, the value displayed in the top part of the display will be a temperature associated to the top

if it flashes, setting of the top set-point will be in progress (with the procedure illustrated in paragraph 14.3)

Advertising