EVCO EVF328J9 User Manual

Page 33

Advertising
background image

EVCO S.p.A.

EVF 300 series | Installer manual ver. 1.1 | Code 144F300E114

Page 33 of 62

Operate as follows to set the floor set-point:

6.

Ensure that the device is switched on and that no

other procedure is in progress.

7.

Press and release the "FLOOR" key: the

LED

and the

LED of the “LOWER” display will flash

and the top part of the display will show the

flashing set-point value.

8.

Press and release the "UP" or "DOWN" key within

15 s to set the set-point value, see also

parameters r7 and r8.

9.

Press and release the "FLOOR" key or do not

operate for 15 s: the “

LED and the

LED”

will switch off and then the device will exit the

procedure.

Operate as follows to exit the procedure before the operation

is complete:

10.

Do not operate for 15 sec (any changes will be

saved).

It is also possible to set the floor set-point via parameter SP2.

14.4

Setting the power distributed at

the top and that distributed at

the floor (only if the CFG

parameter is set at 0)

Operate as follows to set the power distributed at the top:

1.

Ensure that the device is switched on and that no

other procedure is in progress.

2.

Press and release the "TOP" key twice: the

LED of the “LOWER” display will flash and the top

part of the display will show the flashing power

value.

3.

Press and release the "UP" or "DOWN" key within

15 s to set the power value, see also parameters

c0 and c1.

4.

Press and release the "TOP" key or do not operate

for 15 s: the

LED will switch off and then the

device will exit the procedure.

Operate as follows to exit the procedure before the operation

is complete:

5.

Do not operate for 15 sec (any changes will be

saved).

It is also possible to set the power distributed at the top via

the parameter Po1.

Setting the floor set-point

Setting the power distributed at the top

Advertising
This manual is related to the following products: