EVCO EVF328J9 User Manual

Page 44

Advertising
background image

EVCO S.p.A.

EVF 300 series | Installer manual ver. 1.1 | Code 144F300E114

Page 44 of 62

i15

0

1

- - -

1

1

effect caused by the activation of the electric absorption

protection input

0 = DISABLING STEAM INJECTION, SWITCH-OFF OF

STEAM GENERATOR, OF THE TOP OUTPUT AND

THE FLOOR OUTPUT - steam injection will be

disabled, the steam generator, the top output

and the floor output will be switched off; the

display will show the flashing “AL2” code and

the buzzer will be activated (until the input is

deactivated)

1 = “ENERGY SAVING” FUNCTION ACTIVATION - the

“energy saving” function will be activated (while

the input is deactivated)

i16

0

1

- - -

0

0

type of electric absorption protection input contact

0 = normally open (input active with closed contact)

1 = normally closed (input active with open contact)

PARAM.

MIN.

MAX.

U.M.

INP. 1

INP. 2

DIGITAL OUTPUTS

u1

0

1

- - -

0

0

utility managed by the digital output K4 (9)

0 = EXTRACTION

HOOD - in this case, parameter i0

will have meaning

1 = MULTI-FUNCTION - in this case, the “VENT” key

will have meaning

u11

0

1

- - -

0

0

utility managed by the digital output K5 (9)

0 = TECHNICAL

COMPARTMENT

FAN - in this case,

parameter U12 will have meaning

1 = SWITCH-ON/OFF

u12 0 240 min 10 10

technical compartment fan switch-off delay from device

switch-off (only if u11 = 0)

PARAM.

MIN.

MAX.

U.M.

INP. 1

INP. 2

SERIAL NETWORK

LA

1

247

- - -

247

247

device address

Lb

0

3

- - -

2

2

baud rate

0 = 2,400

baud

1 = 4,800

baud

2 = 9,600

baud

3 = 19,200

baud