7

MANAGEMENT OF UTILITIES

7.1

Steam injection

7.1.1

Preliminary notes

The steam injection activation mode depends on parameter t0,

as follows:

-

if the parameter t0 è is set at 0, pressing and

releasing the “STEAM INJECTION” key will cause

the injection of steam for the time established with

parameter tOn or for the entire time the key is

pressed.

-

if parameter t0 is set at 1,pressing and releasing

the “STEAM INJECTION” key will activate steam

injection in cyclic mode (at maximum for the

number of cycles established with the nCY

parameter or until the key is pressed and released

again; the time defined with the tOn parameter

establishes the switch-on duration of the injector

and that established with the tOF parameter,

switch-off) or will cause steam injection for the

entire time the key is pressed.

The steam injection activation consent mode depends on

parameter P4, as follows:

-

if parameter P4 is set at 0, steam injection will be

allowed if the steam generator has been switched

on.

-

if parameter P4 is set at 1, steam injection will be

allowed if the steam generator is on and the multi-

function input has been activated (until the input

has been deactivated and on condition that the

parameter i5 is set at 1).

-

if parameter P4 is set at 2, steam injection will be

allowed if the temperature regulation of the steam

has been activated and the steam temperature is

above that established with the SPS parameter

(until the temperature drops below that

established with parameter t4).

7.1.2

Quick setting of the time tOn (only if the

parameter t0 is set at 0)

The time unit of measurement of the time tOn is the second.

Operate as follows to set the time tOn:

1.

Ensure that the device is switched on and that no

other procedure is in progress.

2.

Hold the “STEAM GENERATOR” key down for 1 s:

the “T

ON

” LED will flash and the bottom part of the

"LOWER" display will show the flashing tOn time

value.

3.

Press and release the UP or DOWN key within 15 s

to set the value of the time tOn.

4.

Press and release the "STEAM GENERATOR" key or

do not operate for 15 sec: the “T

ON

” LED and the

bottom part of the "LOWER" display will remain on

and the device will exit the procedure.

Operate as follows to exit the procedure before the operation

is complete:

5.

Do not operate for 15 sec (any changes will be

saved).

It is also possible to set the time tOn via the tOn parameter.

7.1.3

Quick setting of the tOn time, tOF time and

the nCY number (only if parameter t0 is set

at 1)

The time unit of measurement of the time tOn and time tOF is

the second.

Operate as follows to set the time tOn:

1.

Ensure that the device is switched on and that no

other procedure is in progress.

2.

Hold the “STEAM GENERATOR” key down for 1 s:

the “T

ON

” LED will flash and the bottom part of the

"LOWER" display will show the flashing tOn time

value.

3.

Press and release the UP or DOWN key within 15 s

to set the value of the time tOn.

Operate as follows to set the time tOf:

4.

Press and release the “STEAM GENERATOR” key

during setting of the time tOn: the “T

ON

” LED will

switch off, the “T

OFF

” LED will flash and the

bottom part of the "LOWER" display will show the

flashing tOF time value.

5.

Press and release the UP or DOWN key within 15 s

to set the value of the time tOF.

Operate as follows to set the number nCY:

6.

Make sure that parameter t6 is set at 1.

7.

Press and release the “STEAM GENERATOR” key

during setting of the time tOF: the “T

OFF

” LED will

switch off, the “CYCLES LED will flash and the

bottom part of the "LOWER" display will show the

flashing nCY number value.

8.

Press and release the UP or DOWN key within 15 s

to set the value of the number nCY.

9.

Press and release the "STEAM GENERATOR" key or

do not operate for 15 sec: the “CYCLES” LED and

the bottom part of the "LOWER" display will

remain on and the device will exit the procedure.