EVCO EVF328J9 User Manual
Page 36
Advertising
EVCO S.p.A.
EVF 300 series | Installer manual ver. 1.1 | Code 144F300E114
Page 36 of 62
Operate as follows to exit the procedure before the operation
is complete:
11.
Hold the “UP” key and “DOWN” key down for 4 s
before setting “1” (i.e. before point 8: restore will
not be performed).
Make sure that the manufacturer’s settings are
appropriate; see paragraph 14.7 “List of configuration
parameters”.
Advertising
This manual is related to the following products: