c0

0

1

- - -

0

not dis.

enabling the restriction between the power distributed at

the top (Po1) and the power distributed at the floor

(Po2)

1 = YES - setting the power distributed at the top

causes automatic adaptation of the power

distributed at the floor (and vice versa), such to

guarantee that the sum of the two power values

is always 100

c1 1 999 s 80 80

if CFG = 0, cycle time for switch-on of the top output

and the floor output,; see also Po1 and Po2

if CFG = 1, cycle time for switch-on of the top output

and the floor output during the "energy saving" function

(5)

c2

0

1

- - -

0

not dis.

activation of the "quick heating" function at device

switch-on

1 = YES

c3 0 999

°C/°F

(1)

150

not

dis.

temperature of the chamber above which the " quick

heating" function is interrupted

c4 -1 120 s

15 15

duration of the activation of the buzzer on conclusion of

the cooking timer count (6)

-1 = the buzzer must be silenced by pressing and

releasing the key

c5 0 60 min 20 20

vent activation advance on conclusion of the cooking

timer count; see also c6

c6

0

60

min

20

20

duration of vent activation from advance c5

c7

0

60

min

30

30

maximum duration of vent activation in manual mode

c8

0

1

- - -

1

1

time shown on the bottom part of the "UPPER" display

when the device is off

1 = YES

c10

0

240

min

120

120

maximum duration of the "energy saving" function (7)

c12 0 240 min 60 60

time that must pass in absence of operations on keys

(from device switch-on due to effect of the "weekly

programmed switch-on" function), until the function is

activated again

1 = YES

c13 0 100 % 50

not

dis.

percentage reduction of the switch-on durations of the

top output and the floor output during the "energy

saving" function

Advertising