EVCO EVF328J9 User Manual

Page 39

Advertising
background image

EVCO S.p.A.

EVF 300 series | Installer manual ver. 1.1 | Code 144F300E114

Page 39 of 62

P6

0

2

- - -

0

0

information shown in the top part of the "LOWER"

display when the device is on and when a cooking cycle

is in progress

0 = if CFG = 0, power distributed at the top

alternately to power distributed at the floor for

10 s

if CFG = 1, floor temperature

1 = if CFG = 0, power distributed at the top

if CFG = 1, floor set-point

2 = if CFG = 0, power distributed at the floor

if CFG = 1, reserved

P7 0

99/210

°C/°F

(1)

0 0

temperature above which the use temperature alarm is

activated (code “Ht”; relative to the control module use

temperature, i.e. “control module use temperature +

P7”)

0 = no alarm

PARAM.

MIN.

MAX.

U.M.

INP. 1

INP. 2

MAIN REGULATOR

r0 1 99

°C/°F

(1)

5 5

if CFG = 0, work set-point differential (of SP)

if CFG = 1, top set-point differential (of SP1)

r1 0 r2

°C/°F

(1)

50 50

if CFG = 0, minimum work set-point

if CFG = 1, minimum top set-point

r2 r1 999

°C/°F

(1)

350

350

if CFG = 0, maximum work set-point

if CFG = 1, maximum top set-point

r6

1

99

°C/°F (1)

not dis.

5

floor set-point differential (of SP2)

r7 0 r8

°C/°F

(1)

not

dis.

50

minimum

floor

set-point

r8

r7

999

°C/°F (1)

not dis.

350

Maximum floor set-point

r12

0

1

- - -

0

0

enabling the "weekly programmed switch-on" function

1 = YES

r13 0 240 min 240

240

duration of a power supply cut-off that occurs during the

cooking timer count, such to cause the interruption of

the cooking cycle (3)

PARAM.

MIN.

MAX.

U.M.

INP. 1

INP. 2

STEAM INJECTION

SPS

0

999

°C/°F (1)

100

100

steam set-point; see also t3 (only if P4 = 2)

Advertising