Chapter 10: calibration, Calibrating screen’s sensitivity to default level, Calibration – FingerTec Face ID 2 (FEM 800) Manual User Manual

Page 25

Advertising
background image

26

CONTENTS

10

CALIBRATION

Checking the Keyboard

Keyboard Test is for you to check the condition of the key-
board. Menu > Auto Test icon > Keyboard Test

Inspection on the Optical Scanner

To determine the condition of the fingerprint optical scan-
ner you need to run fingerprint test. Once you go into the
Test Fingerprint, Face ID will display a white square on the
screen. Place your finger on the scanner. If you can see
your fingerprint on the white square, the optical scanner
works fine. Otherwise, kindly send your Face ID for check-
ing. Menu > Auto Test icon > Test Fingerprint

Checking the Infrared Camera

To know the condition of the infrared face scanner, you
need to run face test. Face ID will display a square in the
middle of the screen; you have to look into the camera. If
you can see your image in the square, the camera is work-
ing fine. Otherwise, kindly send your Face ID for checking.
Menu > Auto Test icon > Test Face

Is the Time Accurate?

Time is an essence in Face ID and it can’t be compromised.
The Test Time will display date, time, 0 (s): 0 (ms)
Click the screen to start the test. The 0 (s): 0 (ms) will start
to run and every 10ms change the second to 1. If it doesn’t
run well, kindly send your Face ID for checking. Menu >
Auto Test icon > Test Time

Calibrating Screen Sensitivity to
Default Level

Menu > Calibration

The screen will display five dots, one at a time in all cor-
ners of the screen and one at the center. You need to
touch the center of the dot for the system to calibrate
the screen automatically. When the process is done, the
screen will return to the main menu.