Chapter 4: Console Management

GE-DS-242-PoE Managed Ethernet Switch User Manual

125

OBJECT

DESCRIPTION

PoE Temperature Unit 2

Display the current operating temperature of PoE chip unit 2.

The unit 1 is in charge of PoE Port-13~Port-24

Over Temperature
Protection

Enable / Disable over temperature protection.

When the PoE temperature unit 1 / unit2 over 70 degree C then
PoE power budget will be changed by 3 segments as following.

Over 70 Degree C power budget 180 Watts

Over 73 Degree C power budget 170 Watts

Over 76 Degree C power budget 160 Watts

Power limit mode

Allow to configure power limit mode of Web Smart Device. It can
choose :

Port Priority Deliver PoE power by port priority setting

Total Limit. Set limit value of the total POE port provided power
to the PDs.

Power Allocation

Show the total watts usage of PoE Switch.

PoE Function

Can enable or disable the PoE function.

Priority

Set port priority for the POE power management

It can choose the “port priority”, value is :

• Critical

• High

• Low

High priority is “Critical”.

Device class

Class 0 is the default for PDs. However, to improve power
management at the PSE, the PD may opt to provide a signature for
Class 1 to 3.

The PD is classified based on power. The classification of the PD is
the maximum power that the PD will draw across all input voltages
and operational modes. A PD shall return Class 0 to 3 in
accordance with the maximum power draw as specified by Table
4.1.

Current(mA)

It shows the PoE device current Amp.

Consumption [W]

It shows the PoE device current watt.

Power Limit

It can limit the port PoE supply watts.

Per port maximum value must less 15.4, total ports values must less
than the Power Reservation value.

Once power overload detected, the port will auto shut down and
keep on detection mode until PD’s power consumption lower than
the power limit value.