Interlogix GE-DS-242-PoE User Manual

Page 214

Advertising
background image

Chapter 9: Troubleshooting

210

GE-DS-242-PoE Managed Ethernet Switch User Manual

4. Make sure the cable is the right type

5. Turn off the power. After a while, turn on power again

100Base-TX port link LED is lit, but the traffic is irregular

Solution:

Check that the attached device is not set to dedicate full duplex. Some devices
use a physical or software switch to change duplex modes. Auto-negotiation may
not recognize this type of full-duplex setting.

Switch does not power up

Solution:

1. AC power cord not inserted or faulty

2. Check that the AC power cord is inserted correctly

3. Replace the power cord If the cord is inserted correctly, check that the AC
power source is working by connecting a different device in place of the switch.

4. If that device works, refer to the next step.

5. If that device does not work, check the AC power

While IP Address be changed or forgotten admin password

To reset the IP address to the default IP Address “192.168.0.100” or reset the
password to default value. Press the hardware reset button at the front panel
about 10 seconds. After the device is rebooted, you can login the management
WEB interface within the same subnet of 192.168.0.xx.

Reset

Advertising