Address id – ADLINK ND-6018 User Manual

Page 45

Advertising
background image

Command Set

37

3.3 Set

Configuration

@Description

Configure the basic setting of NuDAM, including the address ID, input
range, baud rate, and data format. The new configuration will be
available after executing the command.

@Syntax

%(OldAddr)(NewAddr)(InputRange)(BaudRate)(DataFormat)<CR

>

%

Command leading code. (1-character)

(OldAddr)

NuDAM module original address ID. The
default address ID of a brand new module is
01. The value range of address ID is 00 to FF
in hexadecimal.
(2-character)

(NewAddr)

New address ID, if you don’t want to change
address ID, let new address ID equals to the
old one. (2-character)

(InputRange)

Define analog input range, refers to Table 3-1
for details. (2-character)

(BaudRate)

Define communication baud rate, refers to
Table 3-2 for details. (2-character)

(DataFormat)

Define checksum, integration time and output
data format, refers to Figure 3-1 for details.
(2-character)

@Response

!(Addr)<CR>

or
?(Addr)<CR
>

(Addr)

Address ID.

!

Command is valid.

?

Command is invalid, parameter values are invalid, or
change the setting without grounding the DEFAULT*
pin.

(6011/D, 6012/D, 6013

6014D, 6017, 6018)

Advertising