47

3.10 Read Analog Data

@Description

Read the analog input value from an analog input module at specified
address in a NuDAM network. While for ND-6013, it returns the channel
0 analog data.

@Syntax

#(Addr)<CR>

#

Command leading code

(Addr)

Address ID

@Response

>(InputData)<CR>

>

Delimiter character

(InputData)

The input data represents the analog signal. The
unit of the digits depends on the data format used.
There are four types of data format. The format is
set by the set configuration command.
Delimiter character

@Example

User command:

#06<CR>

Response:

>+1.6888<CR>


Read the analog input module data at address 06 (Hex). The analog
input module response data is +1.6888 units. The unit depends on the
data format.

(6011/D, 6012/D, 6013, 6014D)