Data Format and Input Range
• 89
Two’s complement hexadecimal: CD27<CR>
((-2/5) x 32768) = -13107.2 = CD27H
Example 3:
•
Input Range is
±10 V
•
Input is +4 Volts
Two’s complement hexadecimal: 3333<CR>
((4/10) x 32768) = 13107.2 = 3333H
Example 4:
•
Input Range is Type K thermocouple (range 0
°C to 1000°C)
•
Input is 406.5
°C
Two’s complement hexadecimal: 3408<CR>
((406.5/1000) x 32768 ) = 13320.2 = 3408H
Ohm
•
Data format bit 1 and 0 set to 11 is ohm presentation.
•
This data format including three components.
1. sign (+)
2. digits
3. decimal point
•
Data is sign (+) followed with 5-digits and a decimal point
•
It does not exceed 7-characters
•
Maximum resolution is 0.01ohm, the decimal point is fixed
Example 1:
•
Input Range is Pt-100, -100
°C to +100°C, α=0.00385
•
Input is 120.23 ohm
ohm: +120.23<CR>