Command Set
• 81
@Examples
User command:
~060<CR>
Response:
!0600$#%@~*<CR>
User command:
~0610A#%@~*<CR>
Response:
!06<CR>
User command:
A06F
Response:
!06A1.8<CR>
Read leading code setting is $#%@~* for module address 06 and
change leading code $ to A, then use A06F to read firmware version of
module on address 06.
*** WARNING ***
z
We do not recommend users to change the default setting of
leading code, because it will confuse yourself
z
The leading code change only use the command conflicts other
devices of other brand on the network
z
The changing of leading code is not necessary if all modules in a
network are NuDAMs‘