Command Set

25


Figure 3-1 Data format of Analog Output Setting

*6024 only supports immediate change and engineering units.

7

6

5

4

3

Reserved

Must to be 0

Analog Output Data Unit
00 : Engineering units
01 : % of Full Scale Range
10 : Hexadecimal

Slew Rate

BitCode Voltage Current

0000 immediate change

0001 0.0625

V/sec

0.125

mA/sec

0010 0.125

V/sec

0.250

mA/sec

0011 0.250

V/sec

0.500

mA/sec

0100 0.500

V/sec

1.000

mA/sec

0101 1.000

V/sec

2.000

mA/sec

0110 2.000

V/sec

4.000

mA/sec

0111 4.000

V/sec

8.000

mA/sec

1000 8.000

V/sec

16.00

mA/sec

1001 16.00

V/sec

32.00

mA/sec

1010 32.00

V/sec

64.00

mA/sec

1011 64.00

V/sec

128.0

mA/sec

2

1

0

Checksum

0 : disable

1 : enable

Advertising