2 engineering units – ADLINK ND-6024 User Manual

Page 58

Advertising
background image

52

Data Format

4.2 Engineering

Units

The date is in engineering unit when the bit 1 and 0 of the configuration register
are ‘00’. The data string is composited by 6 characters. Because the output of
ND-6021 is unipolar, the value is always positive.

The meaning of the value depends on the output range setting too. When the
output range is set to 0~10V, the unit of the value is in ‘Volts’. When the output
range is set to 0~20mA or 4~20mA, the unit of the value is in ‘mA’.

• Set bit 1 and bit 0 of data format variable to “00” means the data is

represented in engineering units

• Data string is fixed length of 6 characters. The value is composed of

five decimal digits with a decimal fixed point

• Two digits present the integer part and three present the fraction

Example 4.2.1:

• If the output range is set as 0 to 20 mA

• The desired analog output value is +5.678 mA

The data value should be : 05.678<CR>

Example 4.2.2:

• If the output range is set as 0 to 10 V

• The desired analog output value is +2.345 V

The data value should be : 02.345<CR>