If the camera will not respond to PTZ commands, check the following:

4.4.1 Check Serial Protocol and Wiring Format

Check the mode selection switch to ensure that it is set for the correct protocol. A
solid RX LED will appear if the switch is set for RS-232 but wired for RS-422/485.
See section 2.2.6 for the appropriate wiring schemes.

4.4.2 Ensure Matching Baud Rate

The encoder Baud Rate must match the decoder and all third party PTZ equipment.
Make sure that the camera / control system is set for 9600 BPS or set the encoder
for the correct Baud Rate needed.