KBC Networks H.264 Encoder User Manual

Page 9

Advertising
background image

Encoder User Manual

Manual-H264_ENC-Rev1207A
Copyright © KBC Networks 2012

Page 9 of 49

www.kbcnetworks.com

2.2.6.3 RS-232

(Use RS-232 dip switch selection)
From encoder: TX+

to camera:

Transmit

From encoder: RX+

to camera:

Receive

From encoder: GND to camera:

Ground

2.2.6.4 Known Incompatible Protocols

The following data protocols are not supported by the KBC encoder/decoder:

Sensornet

Biphase & Bilinx, other Bosch proprietary protocols

Kalatel protocols using RS-422. The system is compatible in RS-485 at 9600
Baud Rate

Coaxitron or other “up the coax” PTZ control systems

2.2.7 Alarm Input / Output Parameters

2.2.7.1 Voltage Specification

Contact Closure Specification

DI

Connection Design

TTL-compatible logic levels

Voltage

Trigger
(low)

Logic level 0: 0V ~ 0.4V

Normal
(high)

Logic level 1: 3.1V ~ 30V

Current

10mA ~ 100mA

DO

Connection Design

TTL-compatible logic levels

Voltage

Trigger
(high)

Logic level 0: 2.4V ~ 5V

Normal
(low)

Logic level 1: 0.1V ~ 0.6V

Current

50mA