Troubleshooting
ATCA-7350 Installation and Use (6806800G59G)
178
A.9
Power Exceptions
A.9.1
ATCA-7350 Cannot Be Started
Description
The ATCA-7350 cannot be started.
Solution
To solve the problem, proceed as follows:
1. Make sure that the shelf is powered on properly.
For details, refer to the respective system documentation.
2. If you install an optional component on the ATCA-7350, remove the optional component
and then restart the ATCA-7350.
3. Start another ATCA-7350 in the shelf. If it can be started normally, replace the faulty ATCA-
7350.
4. If the problem persists, see
A.9.2
ATCA-7350 Automatically Shuts Down
Description
The ATCA-7350 automatically shuts down without any explicit reason.
Solution
To solve the problem, proceed as follows:
1. Make sure that each component of the shelf is installed properly. For details, refer to the
respective system documentation. If some components are not installed or are installed
improperly, the ATCA-7350 may automatically shut down.
2. Replace the ATCA-7350.