Auto noise gain – ATEIS UAPg2 User Manual

Page 219

Advertising
background image

UAPG2 MANUAL

Version EN.24


219

Auto Noise Gain


Adjust the audio level of the paging input (P.M.) depending of the ambient noise.
The ambient noise is measured with a sensing microphone connected to the sensing microphone
input (S.M.). Our advice is to use the sensing microphone MSN (Ateïs), but you can also use another
one.

S.M: sensing microphone input

P.M: paging input


Parameter

Range

Comment

Calibration

Button

Click on to start the automatic calibration procedure

Calibration

Lit all along the calibration procedure

Calibration

Lit when the A.N.G is properly calibrate

Over

Indicates the calibration result:

The white noise level needed is over the range.

A pop-up window will shows you what to do.

Under

Indicates the calibration result:

The white noise level needed is under the range.

A pop-up window will show you what to do :

Response speed

Selector

Select here the reaction speed of the A.N.G.

That's means the speed to adapt the P.M. audio level depending of

the ambient noise.

Min Gain

-15 to 0 dB

The minimum AGC level compensation

Max Gain

0 to 15 dB

The maximum AGC level compensation

Sampling time

0.5 to 60 sec

Determine the period time between two ambient noise measures

Noise generator

Meter

White noise level, automatically Adjusted by the calibration