ATEIS UAPg2 User Manual
Page 73
UAPG2 MANUAL
Version EN.24
73
Set Up several UAPG2 Linked together
You can link up to 12 UAPg2 together.
This not a redondant network. That's means if one link fails, the system fails.
•
Link all the UAP together :
Connect each Digilink output to the Digilink input of the next UAP,
with RJ45 cable.
Close the loop by connecting the last UAP to the first (called master).
•
with the master UAP : Tools/Establish Ethernet link
•
If the UAP already has a configuration inside : Tools/clear the MCU data
•
All the UAP must be in the same version (MCU and DSP).
Check all your UAP's version, if necessary you may have to connect with each one UAP,
establish Ethernet link and update.
•
The master must know the physical configuration :
open Tools / Configure machine IP
You can plug and unplug the link and see instantly in this window how many machines are
detected. Check your cable until the detected machine count becomes match with the number of
UAP.
If one of the links is broken or absent, the detected machine will be 1.
As soon you see the right machine count, write the number of UAP in the Machine Count box, and
click on "Configure" button.
If you cannot get the "Normal status", the problem can come from the UAPg2 version. In that case
establish the connection with each UAPg2 individually, and then update them to the latest version.
(see
Check UAPg2 version
)
The system is configured properly, "when Net Status: Normal" is displayed.