2-21

Error 43: photo cell
lighted too early

automatic flap length detection with
photo cell enabled; photo cell
detected flap end too early

program security length shorter; switch off monito-
ring (enter 250 mm as seam length); check photo
cell TS31 and foil; reduce sensitivity of photo cell
(in case of reflections)

Error 45 ... 48: I/O DAC,
ULN, 485, RES

internal hardware errors during data
transmission to 9020020

replace 9020020

Error 51: Flap station
does not swing

flap station hasn’t reached active
position within error time

check cylindre, valve Y17, termination switch
TS08

Error 52: Flap station
not in home position

flap station hasn’t reached home
position within error time

check cylindre, valve Y17, termination switch
TS07

Error 53: Pocket pouch
station not in home
position

pocket puch supply hasn’t reached
home position within error time

check cylindre, valves Y18 Y19, termination
switch TS11

Error 54: Station not
locked

folder station isn’t locked

lock station; check termination switch TS02