Beisler 100-54 User Manual

Page 71

Advertising
background image

3-17

2.11 Stamp

2.12 Flap clamp adjustment

2.12.1 F l a p clamp pressure

Adjust the flap clamp so that he closing pressure is dis-
tributed evenly along the entire length.

To ensure this, slightly bend the upper clamp strap (1)
downward (use caution!).

2.12.2 Flap clamp height

In the ‘I/O Test’, enable outputs 15, 17, and 24.

The flap clamp (1) must protrude above the sliding
plate (4) by the distance (A = 10 mm).

Loosen the Allen screw (3) and reposition the flap clamp
until the correct distance is set, then tighten the Allen
screw (3).

2.12.3 Parallelism to the folder

In the ‘I/O Test’, enable outputs 15, 17, and 24.

The flap clamp (1) must be parallel to the folder (2).
Loosen the Allen Screw (3) and reposition the flap
clamp (1) until it is exactly parallel.

Tighten the Allen screw (3).