3-9

1.11 Lateral clamp adjustment without

quick adjustments

Mount the folder for the double piping. Adjust the inner
setting rings (2) (3) in a way that there is a distance of
1.5 mm between main clamp and sole.

Mount the folder for single piping. Move clamp and set-
ting rings (3) (4) to the outside until there is a distance of
1.5 mm between folder and sole.

Now block the lateral escape of the clamp arms by fi-
xing the setting rings.

1.12 Clamp adjustment double piping –

flap without quick adjustment

Here you will have to move one clamp arm with the set-
ting rings when changing between folder double or sin-
gle piping.

Loosen the setting ring (3) or (4) and move them toge-
ther with the clamp arm until there is a distance of 1.5
mm between double piping/flap and main clamp.

1.13 Adjust folding slide path

<power off> <release pressure>

The distance between the folding slide (1) driven in and
out must be 5 mm.

If required you can adjust the setting screw (2) at the
cylinder (3).