2 mounting to flowtop linear valves, Ounting to, Inear – Flowserve 500+ Series Logix User Manual

Page 13: Alves

Advertising
background image

User Instructions - Logix® 500+ Series Digital Positioners FCD LGENIM0105-10 11/13

flowserve.com

13


5.2

Mounting to FlowTop Linear Valves


To mount a Logix 500+ positioner to a FlowTop linear
actuator and valve (with direct mounting / integrated tubing),
proceed as outlined below.

1

Remove the FlowTop port plug screw. Plug port B.

2

Ensure positioner O-ring surface is clean. Then install
the O-ring, and FlowTop mounting block using the
positioner screws.

3

Attach the follower arm to the feedback shaft using the
follower arm nut.


FlowTop Port

Spacer

Positioner O-ring

FlowTop Mounting Bracket

Positioner Screws

Follower Arm

Feedback Shaft

Follower Arm Nut

Port B

Figure 5: FlowTop Mounting Bracket