20 HOW TO ORDER

20.1 Positioners


Table 27: 500+ Positioner Configurations

Selection

Description

Code Example

Base Model

Logix 500+ Series

5

5

Communications and

Diagnostics

HART; 8-DIP Set-Up with LCD Option; Standard (Basic Functionality)

1, 2

20MD+

20M

D

+

HART; 8-DIP Set-Up with LCD Option; Advanced (With Pressure Sensing)

1, 2

21MD+

HART; 8-DIP Set-Up with LCD Option; Pro (With Full ValveSight Diagnostics)

1

22MD+

Certifications

General Purpose

14

37

Intrinsically Safe, IP66, North America/ATEX/IECEx Ex ia

37

Positioner Configuration

-

Housing

Aluminum - Black Base with White Cover

W

W

Aluminum - Black Base with Yellow Cover

Y

Aluminum - Black Base with Black Cover (Automax)

B

Aluminum - Black Base with Black Cover (Accord)

A

Threaded Connections

Mounting: 5/16" 18 UNC, Pneumatics: 1/4" NPTF, Conduit: 1/2" NPTF, Vents 1/4" NPTF

1

1

Mounting: M8 x 1.25, Pneumatics: 1/4" NPTF, Conduit: M20 x 1.5, Vents 1/4" NPTF

2

Mounting: M8 x 1.25, Pneumatics: G1/4", Conduit: M20 x 1.5, Vents G1/4"

3

Feedback Shaft

D - 316 Stainless Steel Shaft (Valtek Standard)

D

D

NAMUR - 316 Stainless Steel Shaft (VDI/VDE 3845)

R

Action

Three-way (Single-Acting), Poppet Style Relay

1

1

Three-way (Single-Acting), Spool Style Relay

2

Four-way (Double-Acting), Spool Style Relay

3

Position Indicator

No Indicator

0

F

Flat Indicator

F

Domed Indicator

D

Special Options

No special options

0

0

Chinese Configuration

6

1

Optional Mechanical Add-Ins

-

Manifold

No Manifold

00

GM

Gauge Manifold - Aluminum (required for gauges)

GM

Pressure Gauges

No Gauges

0

1

Nickel Plated with Brass Internals, psi (bar/kPa)

1

Nickel Plated with Brass Internals. psi (kg/cm2 )

2

SS with SS Internals. psi (bar/kPa)

3

SS with SS Internals. psi (kg/cm2 )

4

UCC Press Test Plug, 1/8" NPT

A

Valve, Tank, Schrader 645A

B

Optional Electronic Add-Ins

-

Display

No LCD

0

1

LCD

6

1

Auxiliary Card Slot 1

Slot 1 - No Card

0

1

Slot 1 - Multi-Function Card

3,

1

Auxiliary Card Slot 2

Slot 2 - No Card

0

0

Slot 2 - Multi-Function Card

3,

1

Limit Switches

or

Remote Mount

No Switches

0

3

Mechanical Limit Switch

4

1

Reed Switch

2

Namur V3 type proximity switch, P+F NJ2-V3-N

4

3

Slot Type NAMUR Sensor, P+F SJ2 S1N

4

4

Slot Type NAMUR Sensor, P+F SJ2 SN

4

5

Namur V3 type proximity switch, P+F NBB2-V3-E2

4

6

Remote Mount Feedback

5,

7

1

HART 6 standard. Can be configured as HART 5 or HART 7 in the field.

2

Can be upgraded to 521MD+ or 522MD+ in the field.

3

Can be configured as Analog Output, Discrete Output or Discrete Input in the field. Slot 2 available only after
slot 1 is filled.

4

Only available for general purpose (certification option 14).

5

Includes adapter board (installed in the positioner) and the low profile remote mount unit (which may be
shipped separately).

6

Only available with the 520MD+ model.