Mounting information, Hv-t3 table box installation, 6huddle-vu – FSR HuddleVU User Manual
Page 6
6
Huddle-VU
MOUNTING INFORMATION
HV-T3 INSTALLATION INSTRUCTIONS
SLOTS USED FOR 5/8" TO
1-1/8" THICK TABLE TOPS
SLOTS USED FOR 1-1/8" TO
1-9/16" THICK TABLE TOPS
3.50" DIAMETER
(2) MOUNTING
CLAMP
(2) MOUNTING
SCREW
MOUNTING
CLAMP AND
MOUNTING
SCREW
INSTALLED
MOUNTING
CLAMP AND
MOUNTING
SCREW
(SEE BELOW)
HV-T3 ASSEMBLY
TABLE
DRILL 3.50" DIAMETER HOLE IN TABLE TOP.
1.
2. INSERT HV-T3 ASSEMBLY AND ORIENT AS REQUIRED.
3. INSTALL MOUNTING CLAMPS TO ASSEMBLY AND SECURE TO TABLE BY
SCREWING MOUNTING SCREWS TO UNDERSIDE OF TABLE.
MAKE ELECTRICAL CONNECTIONS AS REQUIRED. ENSURE HDMI
CONNECTOR CAN BE PULLED OUT 3'-0".
4.
CUSTOMER TO PROVIDE
KO SLUG/PENNY/OTHER
HARD FLAT PIECE FOR
SCREW END, WITH SOFT
TABLE WOOD
HV-T3 TABLE BOX INSTALLATION
NOTE: TABLE BOXES ARE AUTOMATICALLY
GROUNDED WHEN THAY ARE PLUGGED INTO AN
AC OUTLET. IF THE UNITS ARE NOT PLUGGED
INTO AN AC OUTLET THEY MUST BE MANUALLY
GROUNDED.