have passed if 2 pass readings out of 3 were recorded. This feature is to allow for potential
disruption in areas of high ambient noise.
APTREPORT sets whether or not APT will send reports every time the test passes. Normal
alarms only report if they change state; setting APTREPORT to ON will cause the phone to
send a regular report confirming that it's acoustic components are healthy. By inference this
report also confirms that the phone is powered, running and connected to the network so it
also provides a useful general health check. If the test fails, the phone will not send repeated
reports until at least APTOKCOUNT tests pass again.
APT now will start an APT test within 60 seconds. This button will only start a test if
APTENABLE is set to ON.

5.6 Access

settings

The Access settings page allows the user name and password to be changed.

USERNAME: Can be up to 30 characters long, and can contain only the alphanumeric
characters a-z, A-Z , 0-9 . The default value is “user”. The Username cannot be blank.
IMPORTANT: The word ‘root’ is a reserved username and must not be used or assigned a
password. Setting a user name of "root" will make it impossible to access the phone, and will
require a reset to factory defaults.

PASSWORD
: Can be up to 30 characters long, and can contain only the alphanumeric
characters a-z, A-Z , 0-9 . The default value is "password". Password can be blank if
required.

Note: please make sure to record the user name and password securely. They will be
required to access the phone every time, whether by web page, command line or
configuration file. In the event that the username and password are lost, the unit will
need to be reset to factory defaults. This can be done by holding down a button on the
main circuit board. See section 10.