10.

Reset to Defaults


If the user name and / or password have been lost, the unit can be reset to allow access to its
configuration settings.

To reset to defaults, locate the reset button on the main PCB, next to the HEARTBEAT LED:


NOTE: on Titan and handsfree telephones the main PCB is covered by a plastic backbox
secured by 4 screws. Carefully remove the screws and backbox to expose the circuit boards
underneath.

With the unit powered up (heartbeat flashing), hold the reset button in for 5 seconds, then
release.

The unit will reboot and all configuration settings will revert to factory defaults.

Note all configuration settings will be lost.

The unit will have:
User name : "user"
Password : "password"
IP address ; 192.168.1.2 (static)
Net mask : 255.255.255.0

NOTE: THIS OPTION IS ONLY AVAILABLE ON UNITS FACTORY CONFIGURED WITH
FIRMWARE VERSION 3 AND ABOVE.

Units upgraded to v3 in the field will normally not have this function enabled. Units originally
shipped with v1 or v2 must be returned to factory to have this function enabled.

For Titan and handsfree telephones, carefully replace the backbox replacing the 4 screws.
On Titan models, when replacing the backbox, take care to seat the cables correctly in their
channels as shown.