2 access module command line syntax, 3xe d – GAI-Tronics VoIP Telephone Software Configuration Guide User Manual

Page 74

Advertising
background image

GAI-TRONICS

VoIP Telephone Configuration Guide

Page 74 of 88

9.2

ACCESS Module Command Line Syntax

Action

Verb

Parameters

Comment

1 2

SET

USERNAME UserName

Sets the user name used in local or remote access to
be “UserName”. UserName can be up to 30
characters long, and can contain only the
alphanumeric characters a-z, A-Z , 0-9 . The default
value is “user”. The Username cannot be blank.
IMPORTANT: The word ‘root’ is a reserved
username and must not be used or assigned a
password. Setting a user name of "root" will make it
impossible to access the phone, and will require a
reset to factory defaults.

PASSWORD <Password>

Sets the password used in local or remote access to
be “Password”. <Password> can be up to 30
characters long, and can contain only the
alphanumeric characters a-z, A-Z , 0-9 . The default
value is password.

QUIT

This command returns the user to the login prompt,
effectively logging the user out and returning the CLI
to the secured state.

EXIT

This command returns the user to the top level of the
Command line Interface

SHOW ALL

Shows the current access Name and Password and
also the access error counters

RESET COUNTERS

Resets the access error counters


Note: please make sure to record the user name and password securely. They will be
required to access the phone every time whether by web page, command line or
configuration file.
In the event that the username and password are lost, the unit will need to be reset to
factory defaults. This can be done by holding down a button on the main circuit board.
See section 10.

3XE