Relay board pcb4 - status indicators -21, Relay board pcb4 - status indicators – Hypertherm HT4400 HySpeed Plasma Arc Cutting System User Manual

Page 112

Advertising
background image

MAINTENANCE

HT4400

Instruction Manual

5-21

8

Relay Board PCB4 - Status Indicators

Relay board PCB4 interfaces certain controls in the power supply, ignition console and the valve cluster. The
control board sends a command to the relay board, and the relay board responds by sending 120 VAC to the
control (and also lighting an LED on the relay board). The control board also tells the relay board to shut off the
120 VAC to the particular control (which shuts off the LED). LEDs are located adjacent to the relay that switches
the 120 VAC There are also 4 LEDs indicating on-board conditions.
See page 6-2 for location of Relay Board.

On the following pages are the LEDs that will illuminate under different modes of operation.

REC2

REC3

REC4

REC2

REC3

REC4

Pin#

Description

Pin#

Description

Pin#

Description

5&6

Arc Xfer

1&2

SV-8 on Valve Cluster

1&2

Pump motor in
Cooler via Power
Distribution PCB

3&4

SV-12 on Valve Cluster

3&4

Power to Start Circuit Assy

5&6

SV-11 on Valve Cluster

5&6

Power to Analog PCB

7&8

SV-10 on Valve Cluster

7&8

DC On LT2

9&10

SV-9 on Valve Cluster

9&10

CON1 CON2

11&12

Solid-state ignition in

11&12

Pilot arc relay

Ignition Console

13&14

Choppers 1-4

13&14

Start counter

15&16

Power to Relay Board

15&16

Error counter

Relay Board PCB4 Status Indicators

D22
Power to
Choppers

D16
Analog PCB
power

D20
Output
Enable

D17
Start Circuit
Assy power
(Power Supply)

D15
DC ON

D18
Pump motor
enable
(This relay
enables the
Cooler pump via
the Power
Supply Power
Distribution
Board)

D11
SV-12 Plasma
(Valve Cluster)

D12
SV-11 Plasma
cutflow
(Valve Cluster)

D13
SV-10 Plasma
preflow
(Valve Cluster)

D19
SV-9 Shield
cutflow
(Valve Cluster)

D28
Solid-state ignition
(Ignition console.)

D14
CON1

D7
P.A. Relay

D8
Start Counter

D9
Error Counter

D10
SV-8 Shield
preflow
(Valve Cluster)

D6
+12 VDC

D26
Arc On

Spare
output

Advertising