MAINTENANCE

5-6

HT4400

Instruction Manual

HT4400 Plasma START Sequence

The following flowchart shows the sequence from when the plasma START signal is given up to the RUN state.
Shaded boxes indicate action taken by the operator.

Plasma START Signal Given

¥ Pre-flow gases ON
¥ Main contactor CON1 ON
¥ DC ON lamp ON
¥ Pilot arc relay closes after 1 s
¥ Hold signal released by control board
after 2 s
¥ Phase loss monitored
¥ Interlocks monitored

Control board monitors

Hold signal for 30 s

¥ Gas console displays Hd
¥ All functions disabled until
plasma START signal released

CNC sending a

Hold?

Hold signal

still being sent?

¥ Solid state ignition ON
¥ Choppers 1&2 output
pilot arc current

¥ Gas console displays XF
¥ All functions disabled until
plasma START signal is released.

¥ Solid state ignition OFF
¥ Control board receives arc transfer
signal from Analog board
¥ Choppers 3&4 ON

¥ Start counter output is active
¥ After 100 ms, pilot arc relay OFF
¥ Power supply sends arc transfer signal to CNC
¥ Plasma gas switches from preflow to cut-flow
¥ Control board looks for pierce complete signal
¥ Shield gas switches from preflow to cut-flow after pierce complete
¥ All choppers ramp up to set output current
¥ Control board monitors chopper output

All choppers ramp up
to 100A total output

Arc transfer within 300 ms?

All choppers ramp up
to 200A total output

Set current level > 200A?

Yes

Yes

Yes

Yes

System in RUN mode

Next
Page

No

No

No

No

Phase loss detected?

¥ Main contactor CON1 OFF
¥ Gas console displays PL error
¥ All functions disabled until
plasma START signal is released

Yes